The skid-mounted sewage treatment plant arrives as a fully fabricated unit: tanks, piping, blowers, pumps and PLC control are installed and tested in our workshop before shipment. On site you only place the skid, connect inlet/outlet and power, then start commissioning – typically within days, not months.
Typical Specification
| Capacity | 5 – 500 m³/d |
|---|---|
| Process options | A2O, MBR, contact oxidation |
| Shell material | Carbon steel with epoxy coating / SUS304 |
| Influent BOD₅ | ≤ 400 mg/L (typical domestic sewage) |
| Effluent quality | GB 18918-2002 Class 1-B / 1-A |
| Control | Full-automatic PLC, unattended operation |
Quality Highlights
- All plates double-side welded; every weld passes kerosene leakage test
- Hot-dip galvanized media support frames for long service life
- De-oiled and de-rusted surfaces before coating
- Skid base allows crane handling and fast relocation
Applications
- Villages and townships, schools, hotels, hospitals
- Highway service areas and camps
- Industrial parks with domestic sewage
Typical values are shown for reference. Detailed TDS, COA and test reports are available on request. Custom widths, thicknesses and process configurations are supported.

Reviews